NOVAEOS AC-LA2 Aerator - 120-Volt Electric Aerator

  • Coverage: Up to 2 acres
  • Compressor: 1/4 HP
  • Maximum Airflow: 2.7 SCFM
  • Maximum Depth: Up to 50 ft

Product Overview

The NOVAEOS AC-LA2 is a premium 120-volt electric pond aerator engineered for ponds up to 2 acres. It provides dependable 24-hour subsurface aeration using a USA-made rocking piston compressor, two DB-36 stainless steel diffusers, and a purpose-built outdoor enclosure.

When reliable electrical service is available near the pond, AC-powered aeration is an economical way to circulate oxygen continuously, day and night. By moving air into the lower water column, the AC-LA2 helps reduce stagnation, support fish health, improve circulation, reduce odors, and promote healthier overall pond conditions.

The NOVAEOS AC-Series was designed around airflow, quiet operation, service access, mounting flexibility, and optional intelligent controls. The result is a professional aeration system that is straightforward to install, convenient to maintain, and built for long-term outdoor use.

Key Benefits

• Continuous 120-Volt Aeration: Provides reliable 24/7 operation wherever suitable grid power is available.

• Purpose-Built Outdoor Cabinet: Laser-cut, formed, welded, and powder-coated enclosure designed specifically for aeration equipment.

• Quiet, Serviceable Design: Engineered ventilation, compressor isolation, accessible filters, and organized internal components simplify maintenance.

• Flexible Installation: Standard brackets support pole, post, or wall mounting; an optional ground-mount base kit is available.

• Advanced Control Options: Available factory-installed time clock, automatic Slow Start control, and high-temperature protection.

Purpose-Built Enclosure

The AC-Series cabinet provides protected ventilation, lockable access, and convenient service access to the compressor, filters, pressure gauge, controls, manifold, and air outlets. Dual washable enclosure filters, a screened exhaust outlet, active ventilation, and rubber compressor isolation mounts help support dependable operation and reduced sound transmission.

Optional Controls and Protection

The AC-LA2 may be factory-equipped with a digital time clock and/or the U.S. Solar Mounts automatic Slow Start control. Slow Start gradually increases aerator runtime during initial startup, helping reduce the risk of rapidly mixing low-oxygen bottom water into the upper water column. This is especially useful for new installations, seasonal restarts, and stratified ponds.

An optional high-temperature limit control is also available to provide added protection against overheating. These options give the AC-LA2 scheduling, startup-management, and equipment-protection capabilities that are not commonly available in basic plug-in pond aerators.

The AC-LA2 Kit Includes

  • Complete 120-volt compressor and enclosure system
  • 1/4 HP USA-made rocking piston compressor
  • Two DB-36 stainless steel diffusers
  • Heavy-duty AC power cord
  • Standard pole, post, or wall mounting brackets
  • Built-in liquid-filled pressure gauge
  • Two external diffuser outlet ports with individual balancing valves
  • Automatic pressure-relief valve and circuit protection
  • Installation instructions and U.S.-based technical support

Airline is sold separately. Select sufficient self-weighted airline for both diffuser runs based on the cabinet location and planned diffuser placement.

Technical Specifications

System Capacity

  • Recommended Coverage: Up to 2 acres
  • System Type: Grid-powered subsurface pond aerator
  • Operating Voltage: 120 VAC
  • Frequency: 60 Hz
  • Required Circuit: 15A or 20A GFCI-protected circuit
  • Model / SKU: NOVAEOS AC-LA2 / AC-LA2
  • Country of Origin: USA

Compressor and Air Output

  • Compressor: 1/4 HP, 120-volt rocking piston compressor
  • Compressor Origin: Made in USA
  • Maximum Airflow: 2.7 SCFM
  • Maximum Pressure: 30 PSI
  • Maximum Operating Depth: Up to 50 feet, subject to site conditions
  • Compressor Mounting: Rubber isolation mounts
  • Air Intake: Intake filter/silencer with replaceable cartridge
  • Over-Pressure Protection: Automatic brass pressure-relief valve

Air Distribution

  • Air Outlets: Two external outlet ports with individual airflow-balancing valves
  • Pressure Gauge: Built-in liquid-filled pressure gauge
  • Diffusers Included: Two DB-36 stainless steel diffusers
  • Airline: Sold separately
  • Airflow Control: Individual balancing valve for each diffuser run
  • Configuration: Two-diffuser system for distributed aeration

Enclosure and Mounting

  • Construction: Laser-cut steel, formed and welded
  • Finish: Baked-on polyester powder coat
  • Dimensions: 16.5 in. W × 20.5 in. H × 12 in. D
  • Approximate Weight: 65 lb
  • Standard Mounting: Pole, post, or wall mount
  • Optional Mounting: Ground-mount base kit; adds approximately 6 in. to overall height
  • Hardware: Lockable door latches and serviceable cabinet access

Ventilation and Protection

  • Enclosure Cooling: 117 CFM automatic active ventilation
  • Compressor Cooling: Dedicated long-life compressor cooling fan
  • Thermal Protection: Standard thermal motor protector
  • Optional Protection: High-temperature limit control with automatic restart and lockout
  • Filters: Dual easy-access washable enclosure filters
  • Exhaust: Screened and protected exhaust outlet
  • Circuit Protection: Built-in rocker-style circuit breaker

Available Options

  • Digital Time Clock: Optional factory-installed scheduling control
  • Slow Start Control: Optional factory-installed automatic Slow Start control
  • High-Temperature Limit: Optional temperature-protection package
  • Ground-Mount Base: Optional field-installed base kit
  • Airline and Accessories: Self-weighted airline and splice kits available separately

Electrical Installation Requirements

The AC-LA2 must be supplied from a properly installed 120-volt, 15- or 20-amp GFCI-protected circuit. The installer must verify operating voltage at the compressor while the unit is running under load. Undersized conductors or excessive voltage drop can reduce performance and shorten equipment life.

Warranty and Support

Warranty coverage is provided under the current U.S. Solar Mounts Corp Limited Product Warranty and is subject to applicable registration requirements, exclusions, limitations, and claim procedures. Dealers should use the current approved warranty document supplied by U.S. Solar Mounts rather than reproducing warranty terms independently.

Application assistance and U.S.-based technical support are available for system selection, installation planning, airline sizing, and voltage-drop review.

LEAVE A MESSAGE

Description

NOVAEOS AC-LA2 Aerator - 120-Volt Electric Aerator

  • Coverage: Up to 2 acres
  • Compressor: 1/4 HP
  • Maximum Airflow: 2.7 SCFM
  • Maximum Depth: Up to 50 ft

Product Overview

The NOVAEOS AC-LA2 is a premium 120-volt electric pond aerator engineered for ponds up to 2 acres. It provides dependable 24-hour subsurface aeration using a USA-made rocking piston compressor, two DB-36 stainless steel diffusers, and a purpose-built outdoor enclosure.

When reliable electrical service is available near the pond, AC-powered aeration is an economical way to circulate oxygen continuously, day and night. By moving air into the lower water column, the AC-LA2 helps reduce stagnation, support fish health, improve circulation, reduce odors, and promote healthier overall pond conditions.

The NOVAEOS AC-Series was designed around airflow, quiet operation, service access, mounting flexibility, and optional intelligent controls. The result is a professional aeration system that is straightforward to install, convenient to maintain, and built for long-term outdoor use.

Key Benefits

• Continuous 120-Volt Aeration: Provides reliable 24/7 operation wherever suitable grid power is available.

• Purpose-Built Outdoor Cabinet: Laser-cut, formed, welded, and powder-coated enclosure designed specifically for aeration equipment.

• Quiet, Serviceable Design: Engineered ventilation, compressor isolation, accessible filters, and organized internal components simplify maintenance.

• Flexible Installation: Standard brackets support pole, post, or wall mounting; an optional ground-mount base kit is available.

• Advanced Control Options: Available factory-installed time clock, automatic Slow Start control, and high-temperature protection.

Purpose-Built Enclosure

The AC-Series cabinet provides protected ventilation, lockable access, and convenient service access to the compressor, filters, pressure gauge, controls, manifold, and air outlets. Dual washable enclosure filters, a screened exhaust outlet, active ventilation, and rubber compressor isolation mounts help support dependable operation and reduced sound transmission.

Optional Controls and Protection

The AC-LA2 may be factory-equipped with a digital time clock and/or the U.S. Solar Mounts automatic Slow Start control. Slow Start gradually increases aerator runtime during initial startup, helping reduce the risk of rapidly mixing low-oxygen bottom water into the upper water column. This is especially useful for new installations, seasonal restarts, and stratified ponds.

An optional high-temperature limit control is also available to provide added protection against overheating. These options give the AC-LA2 scheduling, startup-management, and equipment-protection capabilities that are not commonly available in basic plug-in pond aerators.

The AC-LA2 Kit Includes

  • Complete 120-volt compressor and enclosure system
  • 1/4 HP USA-made rocking piston compressor
  • Two DB-36 stainless steel diffusers
  • Heavy-duty AC power cord
  • Standard pole, post, or wall mounting brackets
  • Built-in liquid-filled pressure gauge
  • Two external diffuser outlet ports with individual balancing valves
  • Automatic pressure-relief valve and circuit protection
  • Installation instructions and U.S.-based technical support

Airline is sold separately. Select sufficient self-weighted airline for both diffuser runs based on the cabinet location and planned diffuser placement.

Technical Specifications

System Capacity

  • Recommended Coverage: Up to 2 acres
  • System Type: Grid-powered subsurface pond aerator
  • Operating Voltage: 120 VAC
  • Frequency: 60 Hz
  • Required Circuit: 15A or 20A GFCI-protected circuit
  • Model / SKU: NOVAEOS AC-LA2 / AC-LA2
  • Country of Origin: USA

Compressor and Air Output

  • Compressor: 1/4 HP, 120-volt rocking piston compressor
  • Compressor Origin: Made in USA
  • Maximum Airflow: 2.7 SCFM
  • Maximum Pressure: 30 PSI
  • Maximum Operating Depth: Up to 50 feet, subject to site conditions
  • Compressor Mounting: Rubber isolation mounts
  • Air Intake: Intake filter/silencer with replaceable cartridge
  • Over-Pressure Protection: Automatic brass pressure-relief valve

Air Distribution

  • Air Outlets: Two external outlet ports with individual airflow-balancing valves
  • Pressure Gauge: Built-in liquid-filled pressure gauge
  • Diffusers Included: Two DB-36 stainless steel diffusers
  • Airline: Sold separately
  • Airflow Control: Individual balancing valve for each diffuser run
  • Configuration: Two-diffuser system for distributed aeration

Enclosure and Mounting

  • Construction: Laser-cut steel, formed and welded
  • Finish: Baked-on polyester powder coat
  • Dimensions: 16.5 in. W × 20.5 in. H × 12 in. D
  • Approximate Weight: 65 lb
  • Standard Mounting: Pole, post, or wall mount
  • Optional Mounting: Ground-mount base kit; adds approximately 6 in. to overall height
  • Hardware: Lockable door latches and serviceable cabinet access

Ventilation and Protection

  • Enclosure Cooling: 117 CFM automatic active ventilation
  • Compressor Cooling: Dedicated long-life compressor cooling fan
  • Thermal Protection: Standard thermal motor protector
  • Optional Protection: High-temperature limit control with automatic restart and lockout
  • Filters: Dual easy-access washable enclosure filters
  • Exhaust: Screened and protected exhaust outlet
  • Circuit Protection: Built-in rocker-style circuit breaker

Available Options

  • Digital Time Clock: Optional factory-installed scheduling control
  • Slow Start Control: Optional factory-installed automatic Slow Start control
  • High-Temperature Limit: Optional temperature-protection package
  • Ground-Mount Base: Optional field-installed base kit
  • Airline and Accessories: Self-weighted airline and splice kits available separately

Electrical Installation Requirements

The AC-LA2 must be supplied from a properly installed 120-volt, 15- or 20-amp GFCI-protected circuit. The installer must verify operating voltage at the compressor while the unit is running under load. Undersized conductors or excessive voltage drop can reduce performance and shorten equipment life.

Warranty and Support

Warranty coverage is provided under the current U.S. Solar Mounts Corp Limited Product Warranty and is subject to applicable registration requirements, exclusions, limitations, and claim procedures. Dealers should use the current approved warranty document supplied by U.S. Solar Mounts rather than reproducing warranty terms independently.

Application assistance and U.S.-based technical support are available for system selection, installation planning, airline sizing, and voltage-drop review.

Why Buy From Us

Have a Question?